Manufacturer & Exporter 350 BAR Proof Sealing Ready Stock Available

Blanking Plate CETOP 3 / NG6 Manufacturer, Supplier & Exporter in India

Manufactured from high-tensile C45 carbon steel with precision-lapped sealing faces, Variety Industrial Products supplies heavy-duty Blanking Plates CETOP 3 / NG6 (NFPA D03 / ISO 4401-03). Designed to blank off unused stations on hydraulic manifold blocks or isolate test circuits, our plates feature CNC-machined O-ring counterbores with premium NBR 90 or Viton seals for 100% bubble-tight sealing up to 350 BAR (5,000+ PSI).

350 BAR
Proof Sealing
ISO 4401-03
CETOP 3 Standard
Ra ≤ 0.8 µm
Lapped Sealing Face
NBR 90 / FKM
Dual O-Ring Option

Key Engineering Parameters

  • Mounting Standard: ISO 4401-03-02 / CETOP RP 121 H (D03)
  • Port Sealing: Blocks P, T, A, B ports simultaneously
  • Circuit Variants: Full Blind, P-T Bypass, and A-B Loop plates
  • Base Material: Precision ground C45 Carbon Steel block
  • Corrosion Protection: Heavy chemical blackodising (black oxide)
  • Fastener Spec: 4x M5 socket head cap screws (Class 12.9)
ISO 9001:2015 Plant O-Rings Included Same-Day Dispatch Worldwide Export

Technical Specifications – CETOP 3 / NG6 Blanking Plates

Manufactured to ISO 4401-03-02, NFPA D03, and CETOP RP 121 H international hydraulic mounting standards.

Technical Parameter Standard Steel Blanking Plate P-to-T Bypass Plate A-to-B Interconnect Loop Plate
Interface Standard ISO 4401-03-02 / CETOP 3 / NFPA D03 ISO 4401-03-02 / CETOP 3 / NFPA D03 ISO 4401-03-02 / CETOP 3 / NFPA D03
Max Operating Pressure 350 BAR (5,076 PSI) 350 BAR (5,076 PSI) 350 BAR (5,076 PSI)
Proof Pressure Test 525 BAR (Zero Leakage) 525 BAR (Zero Leakage) 525 BAR (Zero Leakage)
Plate Dimensions (L x W x H) 70 mm x 48 mm x 12 mm 70 mm x 48 mm x 15 mm 70 mm x 48 mm x 15 mm
Port Isolation Pattern All P, T, A, B ports fully blinded P & T connected internally; A & B blocked A & B connected internally; P & T blocked
Base Material High-Tensile Carbon Steel C45 High-Tensile Carbon Steel C45 High-Tensile Carbon Steel C45
Sealing Face Flatness < 0.008 mm across mounting face < 0.008 mm across mounting face < 0.008 mm across mounting face
Surface Roughness (Ra) Ra ≤ 0.8 µm (Precision Surface Ground) Ra ≤ 0.8 µm (Precision Surface Ground) Ra ≤ 0.8 µm (Precision Surface Ground)
O-Ring Seals Supplied 4x 9.25 x 1.78 mm NBR 90 Shore (or FKM) 4x 9.25 x 1.78 mm NBR 90 Shore (or FKM) 4x 9.25 x 1.78 mm NBR 90 Shore (or FKM)
Mounting Bolt Pattern 4x Ø5.5 mm thru-holes with M5 C-bore 4x Ø5.5 mm thru-holes with M5 C-bore 4x Ø5.5 mm thru-holes with M5 C-bore
Recommended Bolt Spec M5 x 25 mm Grade 12.9 SHCS (9.0 Nm) M5 x 30 mm Grade 12.9 SHCS (9.0 Nm) M5 x 30 mm Grade 12.9 SHCS (9.0 Nm)
Corrosion Protection Heavy Chemical Blackodising Heavy Chemical Blackodising Heavy Chemical Blackodising

Engineering Highlights – Precision Quality & Reliability

Why industrial hydraulic OEM manufacturers specify Variety Industrial blanking plates.

Sub-Micron Lapped Sealing Faces

Sealing faces are precision ground and lapped to Ra ≤ 0.8 µm with flatness under 8 microns, preventing extrusion or micro-leakage at 350 BAR working pressures.

Precision CNC O-Ring Counterbores

Dovetail and standard retention grooves are CNC machined with exact depth tolerances, ensuring optimal 15–20% O-ring squeeze without pinching or extrusion.

High-Tensile C45 Solid Plate Core

Solid forged/rolled steel construction prevents plate bowing or center dish deflection under sudden hydraulic shock loads and pressure spikes.

NBR 90 Shore & Viton Compatibility

Supplied standard with high-hardness NBR 90 Shore A seals. Optional FKM (Viton) seals allow reliable operation with synthetic fire-resistant fluids up to +180°C.

P-T Bypass & Loop Circuit Flexibility

Beyond full blind plates, our bypass plates allow circulating pump delivery fluid directly back to the reservoir, avoiding relief valve heat generation.

100% Interoperability & Mass Stock

Guaranteed 100% interchangeable with Bosch Rexroth, Parker, Eaton, and Vickers subplates. Thousands maintained in ready stock for emergency plant breakdown dispatches.

Circuit Configurations & Ordering Part Numbers

Select the appropriate internal port routing for your hydraulic power pack design.

Model Code Circuit Type Port P Port T Port A Port B Typical Application
VIP-BP-03-BLIND Full Isolation / Blind Blocked Blocked Blocked Blocked Blanking off spare stations for future expansions
VIP-BP-03-PT P-to-T Bypass Plate Connected Internally (P → T) Blocked Blocked Zero-load pump circulation on tandem center circuits
VIP-BP-03-AB A-to-B Interconnect Blocked Blocked Connected Internally (A ↔ B) Pressure testing lines, cylinder loop flushing
VIP-BP-03-ALL All Cross-Connected All Ports Connected Internally (P + T + A + B) System chemical flushing and oil filtration loops

5-Step Subplate Port Sealing & Installation Guide

Ensure zero weeping and perfect O-ring compression with recommended factory practices.

1
Depressurize System

Shut down hydraulic pump and release accumulator pressure to 0 BAR before loosening any manifold hardware.

2
Clean Mating Face

Wipe manifold pad with lint-free cloth and solvent. Inspect for nicks, scratches, or trapped particulate around port counterbores.

3
Seat O-Rings with Oil

Apply clean hydraulic fluid or petroleum jelly to the 4 supplied NBR 90 O-rings to retain them in place during plate alignment.

4
Fasten M5 Class 12.9 Screws

Insert 4 high-tensile M5 socket cap screws. Hand-tighten evenly until plate seats squarely against manifold surface.

5
Torque to 8.5–9.0 Nm

Using a calibrated torque wrench, tighten screws in a criss-cross diagonal sequence to final 8.5–9.0 Nm torque rating.

Manufactured at Sidhpur, Gujarat – Plant Floor Batch Quality

Strict batch tolerance checks and ultrasonic degreasing on every production lot.

Batch of precision blackodised CETOP 3 blanking plates on Sidhpur inspection table
Batch Chemical Blackodising

Heavy oxide finish provides long-term oxidation protection in harsh plant environments.

Quality inspection of blanking plates and Dowty flanges at Sidhpur facility
100% Dimensional Inspection

Hole PCD and counterbore depths verified with precision digital height gauges and plug gauges.

Hydraulic manifold assembly testing at Sidhpur plant
Manifold Block Matching

Tested on genuine Variety Industrial NG6 multi-station manifolds to ensure flawless seal fitment.

Frequently Asked Questions – Blanking Plates CETOP 3

Answers to common customer and distributor questions.

What is the exact purpose of a CETOP 3 blanking plate?
A CETOP 3 blanking plate is used to securely seal off unused valve stations on multi-station hydraulic subplates or manifold blocks. By bolting the plate over the idle valve pad, the P, T, A, and B internal hydraulic channels are isolated, allowing the rest of the manifold to operate at full pressure without oil leakage.
Can these blanking plates withstand continuous 350 BAR pressure?
Yes. Variety Industrial blanking plates are machined from solid high-tensile C45 carbon steel with 12 mm solid thickness. They easily withstand 350 BAR (5,076 PSI) continuous working pressure with a burst pressure rating exceeding 1,000 BAR.
Are O-rings included with the plate?
Yes, 4 factory-fitted high-grade NBR 90 Shore A O-rings are included with every blanking plate. For high-temperature environments (up to +180°C) or fire-resistant phosphate ester fluids, we provide FKM Viton O-rings on request.
What is the difference between a Blind Plate and a P-T Bypass Plate?
A standard Blind Plate blocks all four ports (P, T, A, B) completely. A P-T Bypass Plate has an internal CNC machined passage connecting the P (Pressure) port directly into the T (Tank) port. This allows the hydraulic pump to unload at minimal pressure when the station is not equipped with a working valve.
Which valves and manifolds is this plate compatible with?
Our blanking plate conforms 100% to ISO 4401-03-02, NFPA D03, and CETOP RP 121 H (CETOP 3). It mounts perfectly onto any manifold designed for Bosch Rexroth (WE6), Parker (D1VW), Vickers (DG4V-3), Yuken (DSG-01), or Polyhydron valves.
What bolt length should be used?
For our 12 mm thick standard blind plate, we recommend M5 x 25 mm or M5 x 30 mm Class 12.9 socket head cap screws, providing at least 10–12 mm of full thread engagement into the manifold block.
Do you offer OEM private labeling or bulk packaging?
Yes. For hydraulic component distributors, cylinder manufacturers, and overseas exporters, we provide laser-marked part numbering, custom branding, and rust-preventive bulk packaging.
OEM & CUSTOM MANUFACTURING

Require Custom Machined Components or 3D STEP Reviews?

Our mechanical engineering team in Sidhpur works directly with technical drawings, 3D STEP models, and custom hydraulic schematics. Send us your project requirements for a quick consultation.