Blanking Plate CETOP 3 / NG6 Manufacturer, Supplier & Exporter in India
Manufactured from high-tensile C45 carbon steel with precision-lapped sealing faces, Variety Industrial Products supplies heavy-duty Blanking Plates CETOP 3 / NG6 (NFPA D03 / ISO 4401-03). Designed to blank off unused stations on hydraulic manifold blocks or isolate test circuits, our plates feature CNC-machined O-ring counterbores with premium NBR 90 or Viton seals for 100% bubble-tight sealing up to 350 BAR (5,000+ PSI).
Key Engineering Parameters
- Mounting Standard: ISO 4401-03-02 / CETOP RP 121 H (D03)
- Port Sealing: Blocks P, T, A, B ports simultaneously
- Circuit Variants: Full Blind, P-T Bypass, and A-B Loop plates
- Base Material: Precision ground C45 Carbon Steel block
- Corrosion Protection: Heavy chemical blackodising (black oxide)
- Fastener Spec: 4x M5 socket head cap screws (Class 12.9)
Technical Specifications – CETOP 3 / NG6 Blanking Plates
Manufactured to ISO 4401-03-02, NFPA D03, and CETOP RP 121 H international hydraulic mounting standards.
| Technical Parameter | Standard Steel Blanking Plate | P-to-T Bypass Plate | A-to-B Interconnect Loop Plate |
|---|---|---|---|
| Interface Standard | ISO 4401-03-02 / CETOP 3 / NFPA D03 | ISO 4401-03-02 / CETOP 3 / NFPA D03 | ISO 4401-03-02 / CETOP 3 / NFPA D03 |
| Max Operating Pressure | 350 BAR (5,076 PSI) | 350 BAR (5,076 PSI) | 350 BAR (5,076 PSI) |
| Proof Pressure Test | 525 BAR (Zero Leakage) | 525 BAR (Zero Leakage) | 525 BAR (Zero Leakage) |
| Plate Dimensions (L x W x H) | 70 mm x 48 mm x 12 mm | 70 mm x 48 mm x 15 mm | 70 mm x 48 mm x 15 mm |
| Port Isolation Pattern | All P, T, A, B ports fully blinded | P & T connected internally; A & B blocked | A & B connected internally; P & T blocked |
| Base Material | High-Tensile Carbon Steel C45 | High-Tensile Carbon Steel C45 | High-Tensile Carbon Steel C45 |
| Sealing Face Flatness | < 0.008 mm across mounting face | < 0.008 mm across mounting face | < 0.008 mm across mounting face |
| Surface Roughness (Ra) | Ra ≤ 0.8 µm (Precision Surface Ground) | Ra ≤ 0.8 µm (Precision Surface Ground) | Ra ≤ 0.8 µm (Precision Surface Ground) |
| O-Ring Seals Supplied | 4x 9.25 x 1.78 mm NBR 90 Shore (or FKM) | 4x 9.25 x 1.78 mm NBR 90 Shore (or FKM) | 4x 9.25 x 1.78 mm NBR 90 Shore (or FKM) |
| Mounting Bolt Pattern | 4x Ø5.5 mm thru-holes with M5 C-bore | 4x Ø5.5 mm thru-holes with M5 C-bore | 4x Ø5.5 mm thru-holes with M5 C-bore |
| Recommended Bolt Spec | M5 x 25 mm Grade 12.9 SHCS (9.0 Nm) | M5 x 30 mm Grade 12.9 SHCS (9.0 Nm) | M5 x 30 mm Grade 12.9 SHCS (9.0 Nm) |
| Corrosion Protection | Heavy Chemical Blackodising | Heavy Chemical Blackodising | Heavy Chemical Blackodising |
Engineering Highlights – Precision Quality & Reliability
Why industrial hydraulic OEM manufacturers specify Variety Industrial blanking plates.
Sub-Micron Lapped Sealing Faces
Sealing faces are precision ground and lapped to Ra ≤ 0.8 µm with flatness under 8 microns, preventing extrusion or micro-leakage at 350 BAR working pressures.
Precision CNC O-Ring Counterbores
Dovetail and standard retention grooves are CNC machined with exact depth tolerances, ensuring optimal 15–20% O-ring squeeze without pinching or extrusion.
High-Tensile C45 Solid Plate Core
Solid forged/rolled steel construction prevents plate bowing or center dish deflection under sudden hydraulic shock loads and pressure spikes.
NBR 90 Shore & Viton Compatibility
Supplied standard with high-hardness NBR 90 Shore A seals. Optional FKM (Viton) seals allow reliable operation with synthetic fire-resistant fluids up to +180°C.
P-T Bypass & Loop Circuit Flexibility
Beyond full blind plates, our bypass plates allow circulating pump delivery fluid directly back to the reservoir, avoiding relief valve heat generation.
100% Interoperability & Mass Stock
Guaranteed 100% interchangeable with Bosch Rexroth, Parker, Eaton, and Vickers subplates. Thousands maintained in ready stock for emergency plant breakdown dispatches.
Circuit Configurations & Ordering Part Numbers
Select the appropriate internal port routing for your hydraulic power pack design.
| Model Code | Circuit Type | Port P | Port T | Port A | Port B | Typical Application |
|---|---|---|---|---|---|---|
| VIP-BP-03-BLIND | Full Isolation / Blind | Blocked | Blocked | Blocked | Blocked | Blanking off spare stations for future expansions |
| VIP-BP-03-PT | P-to-T Bypass Plate | Connected Internally (P → T) | Blocked | Blocked | Zero-load pump circulation on tandem center circuits | |
| VIP-BP-03-AB | A-to-B Interconnect | Blocked | Blocked | Connected Internally (A ↔ B) | Pressure testing lines, cylinder loop flushing | |
| VIP-BP-03-ALL | All Cross-Connected | All Ports Connected Internally (P + T + A + B) | System chemical flushing and oil filtration loops | |||
5-Step Subplate Port Sealing & Installation Guide
Ensure zero weeping and perfect O-ring compression with recommended factory practices.
Shut down hydraulic pump and release accumulator pressure to 0 BAR before loosening any manifold hardware.
Wipe manifold pad with lint-free cloth and solvent. Inspect for nicks, scratches, or trapped particulate around port counterbores.
Apply clean hydraulic fluid or petroleum jelly to the 4 supplied NBR 90 O-rings to retain them in place during plate alignment.
Insert 4 high-tensile M5 socket cap screws. Hand-tighten evenly until plate seats squarely against manifold surface.
Using a calibrated torque wrench, tighten screws in a criss-cross diagonal sequence to final 8.5–9.0 Nm torque rating.
Manufactured at Sidhpur, Gujarat – Plant Floor Batch Quality
Strict batch tolerance checks and ultrasonic degreasing on every production lot.
Batch Chemical Blackodising
Heavy oxide finish provides long-term oxidation protection in harsh plant environments.
100% Dimensional Inspection
Hole PCD and counterbore depths verified with precision digital height gauges and plug gauges.
Manifold Block Matching
Tested on genuine Variety Industrial NG6 multi-station manifolds to ensure flawless seal fitment.
Frequently Asked Questions – Blanking Plates CETOP 3